Metallic Impurities Present in Environmental Water Samples Were Analyzed at Trace Levels Using ICP-MS-KED
DOI:
https://doi.org/10.37591/(rrjops).v14i1.1324Keywords:
Metals, Elemental impurities, Validation, Recovery, Precision, LOD, and LOQAbstract
Elemental impurities in environmental water samples must be carefully monitored since they may have unintended pharmacological and toxicological consequences. For the simultaneous determination of eight metals (Cr, Ni, Cd, Pb, Hg, As, Se, and Sb) in water by ICP-MS, an accurate and sensitive approach has been devised and validated.The method's validity is confirmed through assessment of various criteria for new techniques, including linearity and range, accuracy, precision, selectivity, limit of detection (LOD), and limit of quantitation (LOQ). The present approach demonstrates linear behavior across the 1–1000 ppb range, characterized by r2 values exceeding 0.99. The developed method shows accuracy ranging from 97.5 to 101.7% for water samples. When the relative standard deviation (RSD) of the duplicate metal responses (measured in cps) across three concentration levels is below 1%, the method is considered accurate. This technique allows for the identification and measurement of specific metals at low concentrations owing to its low limits of detection (LOD) and quantitation (LOQ).References
Lubomír, S. Peter, T. Jaroslav, D. Miroslav, R. and Dusan, B. 2012. Analytical Methods for the Detection of Osmium Tetroxide A Review. Polish journal of Environmental Studies, 21(1), 07-13.
Sun, Y. Zhou, M. and Sun, M. 2001. Routine Os analysis by isotope dilution-inductively coupled plasma mass spectrometry: OsO4 in water solution gives high sensitivity. Journal of Analytical and Atomic Spectrometry, 16(4), 345-349.
George, B. Ion, G. and Anca, G. 2005. Thiocyanatochrome complexes in analytical chemistry, Determination of osmium (III). Journal of the Serbian Chemical Society, 70(8-9),1113-1119.
European Medicines Agency, Committee for Medicinal Products for Human Use. 2008.Guideline on the specification limits for residues of metal catalysts or metal reagents. Doc. Ref.EMEA/CHMP/SWP/4446/2000
Pretorius, W. Chipley, D. Kyser, K. and Helmstaedt, H.2003. Direct determination of trace levels of Os, Ir, Ru, Pt and Re in kimberlite and other geological materials using HR-ICP-MS. Journal of Analytical and Atomic Spectrometry,18(4),302-309.
Chawla, RK. Gudhanti, SNKR. Kulandaivelu, U.Panda, SP. and Alavala, RR.2021. Development and validation of an inductively coupled Plasma Mass Spectrometry method for estimation of elemental impurities in calcium acetate active pharmaceutical ingredient, Indian Journal of Pharmaceutical Sciences, 83(4), 830-837.
Ravisankar,M. Alexandar,S. Senthil Kumar,R. Kumar,M. and Venkateswarlu,BS.2022. Validation of the Inductively Coupled Plasma Mass Spectrometry (KED-MODE) Method for Estimation of Class 1 Elemental impurities in Flavoxate hydrochloride-API, Journal of Pharmaceutical Negative results, 13(9),2887-2891.
Ravisankar,M. Alexandar,S. Senthil Kumar,R. Kumar,M. and Venkateswarlu,BS.2022. Determination of Osmium in Azithromycin API using Inductively Coupled Plasma Mass Spectrometry and microwave assisted digestion, Journal of Pharmaceutical Negative results,13(7),7338-7341.
Fuad Al-Rimawi , Khalid Kanan, Mutaz Qutob.2013. Method development and validation of simultaneous determination of seventeen metals in water by ICP/MS.Journal of advances in chemistry,4(3),502-508.
Shchukin,V.M. Zhigilei,E.S. Erina,A.A. Shvetsova,Yu.N . Kuz’mina,N.E and Luttseva,A.I.2020. Validation of an icp-ms method for the determination of mercury, lead, cadmium, and arsenic in medicinal plants and related drug preparations, Pharmaceutical Chemistry Journal, 54, 57–64.
Fernanda Costa, P. Diego Victor, B. Ariane Isis, B. Edenir Rodrigues, P.F and Joaquim, A.N. 2019. Microwave-assisted digestion using dilute nitric acid solution and investigation of calibration strategies for determination of As, Cd, Hg and Pb in dietary supplements using ICP-MS, Journal of Pharmaceutical and Biomedical Analysis, 174, 471–478.
Nageswara Rao,R. and Kumar Talluri, M.V.N.(2007). An overview of recent applications of inductively coupled plasma-mass spectrometry (ICP-MS) in determination of inorganic impurities in drugs and pharmaceuticals, Journal of Pharmaceutical and Biomedical Analysis, 43, 1–13.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |