Computer Simulations on Magnetic Particles Capturing in an Implant Assisted Channel for Targeted Drug Delivery
DOI:
https://doi.org/10.37591/tdd.v2i2.275Abstract
In this paper, we studied the effect of magnetic field, inlet velocity and particle size on capture efficiency of magnetic particles transported in an implant assisted uniform channel through computational simulations. The dominant magnetic and drag forces are included in the simulations. The couple nonlinear Navier-Stokes equation for fluid flow and Newton’s second law equation for particle transport are solved using finite element based COMSOL multiphysics software. It is found that capture efficiency increases from 70–80% as we increase the external magnetic field strength from 2–3.5 Tesla. Further, the decrease in capture efficiency is observed from 80– 60% by increasing the inlet velocity from 20–50 mm/s. Enhancement in capture efficiency from 20–100% is observed by increasing the size of magnetic particles from 100 nm to 1.5 µm, respectively.
Keywords: Targeted drug delivery, magnetic nanoparticles, Ferromagnetic stent
Cite this Article
Prakash Chandra, Shashi Sharma, Anurag Gaur, Dharmendra Tripathi.
Computer Simulations on Magnetic Particles Capturing in an Implant Assisted Channel for Targeted Drug Delivery. Trends in Drug Delivery. 2015; 2(2): 1–7p
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |